Article

Project Management

November 19, 2026

Supervised learning in voltammetric quantification with electrochemical sensors

Thiago Serafim Martins; Iago Cambre Anon

DOI: 10.22167/2675-6528-202603813

Article derived from a Final Course Work (TCC), with content based on the student’s original work and adapted to the editorial format of the E&S Magazine with the support of the ResumeAI tool, an artificial intelligence solution developed by Instituto Pecege for textual synthesis and organization.

Summary

The application of supervised learning in the voltammetric quantification of paraquat in urine was evaluated. The study aimed to quantitatively evaluate the predictive performance of supervised learning models compared to a univariate “baseline”, preserving the independence between devices in the training and testing sets. The research was conducted as an applied case study, processing data from four physical devices, each evaluated under a blank condition and six paraquat concentration levels, totaling 28 square wave voltammetry (SWV) curves. A computational “pipeline” integrated the automated reading of files, the organization of curves into current-potential matrices, the generation of potential maps, and device-specific blank correction. Five approaches were considered: conventional univariate calibration, predictive univariate “baseline”, partial least squares (PLS) regression, support vector regression (SVR), and random forest (RF). Predictive evaluation was performed by device-grouped cross-validation. PLS showed the best predictive performance for curves from a device not used in training, with an R² of 0.7981. RF exhibited intermediate performance, while SVR and the predictive univariate “baseline” showed inferior and similar performance between themselves. It was concluded that a compact multivariate representation of the voltammetric profile was more favorable for inter-device prediction than increasing model flexibility under the studied conditions. Grouped validation preserved independence, but the limited number of devices restricts the generalization of the results.

Keywords: Supervised learning; Paraquat; PLS; Electrochemical sensors; Square wave voltammetry.

1. Introduction

Electrochemical sensors allow for the qualitative and quantitative detection of chemical species present in environmental, biological, and industrial matrices (Ali et al., 2025; Dodevska et al., 2025; Martins et al., 2024; Meliana et al., 2026). In the context of voltammetric techniques based on faradaic processes, the current response is influenced by the charge transfer kinetics at the electrode-solution interface and by the mass transport conditions of the electroactive species (International Union of Pure and Applied Chemistry, 2025).

Differential pulse voltammetry (DPV) and square wave voltammetry (SWV) stand out among the pulsed techniques widely employed in quantitative analyses. Both use periodic potential perturbations applied over an underlying ramp, producing current responses with high sensitivity and improved signal-to-noise ratio when compared to linear or cyclic voltammetry (Bard and Faulkner, 2001; Brett and Brett, 1993). The obtained responses can present characteristic voltammetric peaks, from which quantitative parameters, such as peak height and integrated charge, can be extracted.

However, the interpretation of these curves becomes more challenging in matrices containing chemical interferents or species with close redox potentials. In these systems, different effects can act simultaneously, compromising the linearity and selectivity of the response. Among the main factors, the following stand out: coupled electrochemical-chemical mechanisms, increased contribution of capacitive currents, peak overlap, instrumental noise and temporal potential drift, and intersensor variability, associated with differences in the electroactive area, surface roughness, or degree of electrode functionalization (Cancelliere et al., 2025; Dokuzparmak et al., 2025; Nashruddin et al., 2024).

These factors reduce the effectiveness of univariate calibrations based on isolated parameters, as this approach uses a single signal descriptor and may fail to consider relevant variations distributed throughout the entire current-potential profile.

Machine learning methods, particularly supervised learning algorithms, offer a suitable alternative for dealing with this multivariate structure. By considering the complete current vector as the input variable, these methods can explore information distributed along the voltammetric profile, including variations in curve shape, signal magnitude, and peak position, potentially relevant in voltammetric analyses of complex systems. Models such as partial least squares regression (PLS), support vector regression (SVR), and random forest (RF) allow for exploring relationships between the multivariate signal profile and analyte concentration through different modeling strategies (Abdi, 2010; Geladi and Kowalski, 1986; Smola and Schölkopf, 2004; Breiman, 2001; Liu et al., 2020; Gregorutti et al., 2017; Bhaiyya et al., 2024; Li et al., 2025).

The quantification of paraquat in artificial urine by SWV presents a scenario where inter-sensor variability and matrix complexity can compromise analytical accuracy. The need for robust methods that preserve independence between devices in training and testing sets is crucial for the practical applicability of electrochemical sensors in real-world scenarios, justifying the investigation of supervised learning approaches.

This study evaluated the application of supervised learning to the quantification of paraquat in artificial urine by SWV. The objective was to quantitatively evaluate the predictive performance of supervised learning models compared to the univariate baseline, preserving the independence between devices in the training and testing sets.

2. Material and Methods

This study was characterized as an applied research, conducted in the form of a single case study. The methodological approach employed focused on evaluating the application of supervised learning to voltammetric quantification, using exclusively secondary data, previously obtained and organized for computational processing.

The empirical object consisted of square wave voltamograms (SWV) of paraquat in artificial urine. The experimental dataset comprised 28 curves, originating from four distinct physical devices. Each device was evaluated under a blank condition (0 mol L⁻¹) and at six paraquat concentration levels, ranging from 1.0 × 10⁻⁶ to 1.0 × 10⁻⁵ mol L⁻¹.

The computational processing of the data was performed in the Jupyter Notebook 7.4.5 environment. A computational “pipeline” was developed for automated file reading, organization of curves into a current-potential matrix, and generation of a potential map. Each curve was converted into a row of a unified table, with current points structured into individual columns, ensuring traceability between files, devices, concentrations, and potentials.

The preprocessing included white correction, specific to each device. The corresponding white curve was subtracted point by point from the curves obtained at different concentrations of the same device, aiming to reduce background contributions. The four white curves were used as a reference for correction and graphical inspection, but did not integrate the predictive modeling set. The models were evaluated from the 24 curves corrected by white, corresponding to the six non-zero concentrations.

For conventional univariate calibration, the potential range of the analyte was defined between -0.8 and -0.5 V, extracting the maximum current value. The mean and standard deviation of the signal per concentration were calculated, adjusting a linear regression. This calibration served as a classic analytical reference. As a simple predictive reference, a univariate “baseline” was implemented, where the variable selection occurred with the curves of the three remaining devices in the training set, identifying the column with the highest absolute correlation and summarizing a local window by the average of the currents for linear regression.

Three supervised learning models were evaluated: partial least squares regression (PLS), support vector regression (SVR), and random forest (RF). PLS used the complete voltammetric profile as input, projecting predictors onto latent components (Abdi, 2010; Geladi and Kowalski, 1986). SVR modeled nonlinear relationships with kernel functions (Smola and Schölkopf, 2004), and RF combined multiple decision trees (Breiman, 2001). For SVR and RF, input and response variables were standardized by StandardScaler, with scalers fitted to the training data.

The predictive evaluation of the supervised models and the univariate “baseline” occurred by device-clustered cross-validation, at two levels. At the external level, the six curves corresponding to the non-zero concentrations of one device were reserved for testing in each iteration, while the curves of the remaining three devices constituted the training set. This procedure was repeated for the four devices, ensuring that each was used only once as the test group.

At the internal cross-validation level, hyperparameters were selected using only the devices from the training set. For PLS, one to five components were evaluated. For SVR and RF, hyperparameter selection was performed by GridSearchCV with internal device-grouped validation, using the lowest average RMSE as the criterion. Model performance was quantified by R², RMSE, and MAE, expressed in mol L⁻¹, calculated from the 24 combined external predictions.

Given that the study exclusively used secondary data, with no participant identification, personal data collection, or direct intervention with human beings, there was no need for submission to the Research Ethics Committee (CEP). The ethical framework of the work was documented through the Ethical Considerations Form (ECF), as per institutional requirement.

3. Results and Discussion

The implementation of the computational “pipeline” developed for this study resulted in the organization of a robust analytical matrix, composed of twenty-eight voltammetric curves, each characterized by six hundred and seventy-two current variables. This structuring ensured precise correspondence between the raw data files, the physical devices used, the paraquat concentrations, and the respective potential values. Four of these curves corresponded to the specific blanks of each device, being used exclusively in the pre-processing and visual inspection steps, while the remaining twenty-four curves, related to non-zero concentrations, were intended for the predictive evaluation of the models.

After the blank correction step, the voltammograms presented a profile where the curves corresponding to the blank samples exhibited zero current across the entire applied potential range. In contrast, samples containing paraquat showed clear response differences, with a more pronounced separation between concentrations observed in the potential range between –0.8 and –0.5 V. A more pronounced signal, indicative of the analyte’s presence, was noted in the region of –0.7 to –0.6 V, which confirmed the effectiveness of the correction in isolating the paraquat response from the background contribution of the matrix and the system.

Conventional univariate calibration

The conventional univariate calibration was established from the maximum current value extracted from each blank-corrected curve, specifically in the potential range between –0.8 and –0.5 V. This approach, based on the average signal of the four devices for each concentration, with error bars representing the standard deviation, revealed a linear fit with a coefficient of determination (R²) of 0.7630. The results indicated a mean trend of increasing current signal as a function of paraquat concentration, although accompanied by notable dispersion among the different devices, which underscores the inter-sensor variability that multivariate methods seek to address.

The dispersion observed in conventional univariate calibration, even with an R² of 0.7630, suggests that inter-device variability is a significant factor that can limit the accuracy of simpler approaches. This variability can be attributed to differences in electroactive area, surface roughness, or electrode functionalization, as discussed in the literature (Cancelliere et al., 2025; Dokuzparmak et al., 2025; Nashruddin et al., 2024). The need to consider the complete voltammetric profile, rather than a single descriptor, becomes evident to mitigate these effects and obtain more robust predictive models.

“Baseline” univariate predictive with device-wise cross-validation

The predictive univariate “baseline”, conceived as a lower complexity reference for comparison with multivariate models, was evaluated by device-grouped cross-validation. This model achieved an R² of 0.4885, an RMSE of 2.2774 × 10⁻⁶ mol L⁻¹, and an MAE of 1.8588 × 10⁻⁶ mol L⁻¹. The analytical region selected for prediction varied among the four external iterations, with the central columns i_153 (–0.63309 V), i_166 (–0.59341 V), i_161 (–0.60867 V), and i_168 (–0.58731 V) being chosen only once each. This variation in the selection of the analytical region demonstrates the sensitivity of the univariate model to the specific composition of the devices present in the training set, indicating a limitation in its ability to generalize across devices.

The performance of the predictive univariate “baseline”, with an R² of 0.4885, was considerably lower than that of conventional univariate calibration (R² = 0.7630), which is explained by the distinct nature of their evaluations. While conventional calibration is descriptive and based on averages, the predictive “baseline” underwent rigorous grouped cross-validation, simulating prediction on a device unseen in training. This difference highlights the importance of validation methods that preserve the independence between datasets for a realistic assessment of predictive performance in practical scenarios, where new devices may be used.

PLS multivariate model

The Partial Least Squares (PLS) Regression model demonstrated the best predictive performance among all evaluated approaches, presenting an R² of 0.7981, an RMSE of 1.4309 × 10⁻⁶ mol L⁻¹, and an MAE of 1.1256 × 10⁻⁶ mol L⁻¹. The selection of the number of components for PLS varied, with three components being chosen in three of the four outer iterations and four components in the remaining iteration. This consistency in selecting a reduced number of latent components, which capture most of the relevant variance in the data, is an indication of PLS’s ability to efficiently compress the multivariate information from the voltammetric profile, optimizing the relationship between model complexity and its predictive power (Abdi, 2010; Geladi and Kowalski, 1986).

The superior performance of PLS can be attributed to its ability to handle datasets with a large number of correlated input variables, as is the case with voltammetric profiles. By projecting the predictors onto latent components that maximize covariance with the response variable (paraquat concentration), PLS can extract relevant information from the entire signal spectrum, mitigating the effects of inter-sensor variability and the complexity of the artificial urine matrix. This multivariate approach proved more effective than selecting a single local region of the voltammogram, as in the univariate “baseline”.

SVR Complementary Supervised Model

The Support Vector Regression (SVR) model showed inferior predictive performance compared to PLS, with an R² of 0.4700, an RMSE of 2.3181 × 10⁻⁶ mol L⁻¹, and an MAE of 1.8642 × 10⁻⁶ mol L⁻¹. For SVR, the hyperparameters C = 10 and gamma = scale were consistently selected in the four outer iterations, while epsilon was selected as 0.10 in three iterations and 0.01 in one. Despite SVR’s inherent ability to model nonlinear relationships through kernel functions (Smola and Schölkopf, 2004), no significant gain in predictive performance was observed in the cross-device validation, with its results being comparable to the univariate “baseline”.

The absence of performance improvement in SVR, even with its flexibility to model nonlinearities, suggests that, under the specific conditions of this study, the complexity of the relationships between the voltammetric profile and paraquat concentration was not predominantly nonlinear, or that the relevant information for prediction between devices was not captured more effectively by this approach. The standardization of input and response variables, although crucial for SVR, was not sufficient to overcome the limitations imposed by inter-device variability and the restricted number of samples.

RF Complementary Supervised Model

Random Forest (RF) demonstrated intermediate performance compared to the other models, with an R² of 0.6453, an RMSE of 1.8964 × 10⁻⁶ mol L⁻¹, and an MAE of 1.5141 × 10⁻⁶ mol L⁻¹. This performance was superior to the univariate “baseline” and SVR, but inferior to PLS. The most frequent hyperparameter configurations for RF included max_depth = None, max_features = sqrt, min_samples_leaf = 1, and n_estimators = 100, selected in three of the four external iterations. In the remaining iteration, the combination was max_depth = None, max_features = 0.5, min_samples_leaf = 2, and n_estimators = 100.

Although RF is capable of modeling nonlinear relationships and interactions between different regions of the voltammogram curve (Breiman, 2001), its intermediate performance may be influenced by the reduced number of independent devices and the high dimensionality of the voltammogram vector, as well as the correlation between adjacent predictors (Gregorutti et al., 2017). The inherent complexity of RF, which builds multiple decision trees, may have been less advantageous than the PLS dimensionality reduction approach for the task of prediction between devices under the evaluated conditions.

Comparison between the approaches

The comparative analysis of the predictive approaches confirmed that PLS achieved the best performance in the three metrics evaluated (R², RMSE, and MAE), outperforming the univariate “baseline”, SVR, and RF. The results indicated that, in this experimental set, the increased model flexibility, as observed in SVR and RF, did not necessarily translate into better predictive performance between devices. This finding suggests that a compact multivariate representation of the voltammetric profile, as provided by PLS, was more favorable for prediction on a device not used in training than the greater non-linear modeling capacity or the use of a single local signal region.

The frequency of the main hyperparameter choices during device-grouped cross-validation revealed distinct patterns for each model. For the predictive univariate “baseline”, there was no predominant central column, with each of the four options (i_153, i_161, i_166, i_168) being selected once. In PLS, three components were chosen in three of the four iterations, demonstrating a preference for low-dimensional representation. For SVR, the parameters C = 10, epsilon = 0.10, and gamma = scale were the most frequent, while for RF, the combinations of max_depth = None, max_features = sqrt, min_samples_leaf = 1, and n_estimators = 100 predominated. These choices reflect the internal strategies of each algorithm to optimize prediction under the constraints of the dataset.

The device-grouped cross-validation strategy was fundamental to preserving independence between the training and test sets, ensuring that the predictive evaluation was more representative of the models’ ability to generalize to a device not used in fitting. However, the limited number of four devices available for the study imposes a restriction on the accuracy of performance estimates and the generalization of results. The variability of the RMSE for PLS, which ranged from approximately 5.18 × 10⁻⁷ to 2.32 × 10⁻⁶ mol L⁻¹ among the devices reserved for testing, reinforces the persistence of inter-device variability, even in the best-performing model.

The generalization of findings to a larger number of devices, new manufacturing batches, real samples, or concentrations outside the studied range requires independent validation. Furthermore, the practical applicability of the proposed analytical workflow presupposes the availability of a specific blank measurement for each new device to be analyzed. This condition is crucial for effective signal correction and for maintaining predictive accuracy, as demonstrated by the importance of the blank correction step in data preprocessing.

In summary, the study demonstrated that PLS, by employing a compact multivariate representation of the voltammetric profile, offered the most robust predictive performance for the quantification of paraquat in artificial urine by SWV, outperforming univariate approaches and other more flexible supervised learning models, such as SVR and RF, under inter-device validation conditions. The results indicate that dimensionality reduction and latent component extraction were more effective in handling inter-sensor variability and matrix complexity than the mere introduction of non-linearities into the model, although the generalization of the findings is limited by the restricted number of devices evaluated.

4. Conclusion

This study evaluated the application of supervised learning in the voltammetric quantification of paraquat in artificial urine by square wave voltammetry (SWV), with the aim of comparing the predictive performance of different models, maintaining independence between devices in the training and testing sets. It was found that partial least squares (PLS) regression showed the best predictive performance, with an R² of 0.7981, for curves from a device not used in training. Random forest (RF) exhibited intermediate performance, while support vector regression (SVR) and the univariate predictive “baseline” showed inferior and comparable results. It was observed that a compact multivariate representation of the voltammetric profile was more effective for inter-device prediction than increasing model flexibility or using a single local signal region. This approach demonstrated the ability to handle inter-sensor variability and the complexity of the artificial urine matrix, offering a significant technical contribution to the development of robust analytical methods in electrochemical sensors.

Despite the demonstrated effectiveness, the limited number of four devices evaluated imposes a limitation on the generalization of results and the precision of performance estimates. The persistence of inter-device variability was noted even in the best-performing model, with the root mean square error (RMSE) of PLS fluctuating among the tested devices. To enhance practical applicability, independent validation of the findings in a larger number of devices, new manufacturing batches, and real samples is suggested, as well as at concentrations outside the studied range. Additionally, the proposed analytical workflow requires the availability of a specific blank measurement for each new device to be analyzed, an essential condition for effective signal correction and the maintenance of predictive accuracy.

Bibliographic References

Abdi, H. 2010. Partial least squares regression and projection on latent structure regression (PLS Regression). Wiley Interdisciplinary Reviews: Computational Statistics 2(1): 97-106.

Ali, T.; Bashir, N.; Hussain, T.; Afzal, A. 2025. Group-selective recognition of anionic dyes in groundwater: ultrasensitive electrochemical sensors for industrial-scale monitoring and controlled release of effluents. ACS Sustainable Resource Management 2(8): 1363-1372.

Bard, A.J.; Faulkner, L.R. 2001. Electrochemical methods: fundamentals and applications. 2ed. John Wiley & Sons, New York, NY, EUA.

Bhaiyya, M.; Panigrahi, D.; Rewatkar, P.; Haick, H. 2024. Role of machine learning assisted biosensors in point-of-care testing for clinical decisions. ACS Sensors 9(9): 4495-4519.

Breiman, L. 2001. Random forests. Machine Learning 45(1): 5-32.

Brett, C.M.A.; Brett, A.M.O. 1993. Electrochemistry: principles, methods, and applications. Oxford University Press, Oxford, UK.

Cancelliere, R.; Molinara, M.; Licheri, A.; Maffucci, A.; Micheli, L. 2025. Artificial intelligence-assisted electrochemical sensors for qualitative and semi-quantitative multiplexed analyses. Digital Discovery 4(2): 338-342.

Dodevska, T.; Hadzhiev, D.; Dimcheva, N. 2025. Highly selective and stable electrochemical sensor for hydrogen peroxide—application in cosmetics quality control. Chemosensors 13(11): 376.

Dokuzparmak, E.; Sezer, E.; Güner, T.; Yaşar, E.; Özçelik, H.; Akgöl, S. 2025. Hybrid intelligence-driven nanopolymeric sensor for precise electrochemical vitamin C analysis, free from LoD: application in real lemon juice. ACS Applied Electronic Materials 7(15): 6980-6993.

Geladi, P.; Kowalski, B.R. 1986. Partial least-squares regression: a tutorial. Analytica Chimica Acta 185: 1-17.

Gregorutti, B.; Michel, B.; Saint-Pierre, P. 2017. Correlation and variable importance in random forests. Statistics and Computing 27: 659-678.

International Union of Pure and Applied Chemistry [IUPAC]. 2025. Electrochemical sensor. In: International Union of Pure and Applied Chemistry. The IUPAC compendium of chemical terminology. 5ed. Disponível em: <https://goldbook.iupac.org/terms/view/09072>. Acesso em: 10 jun. 2026.

Li, A.; Yang, H.; Yu, W.; Liu, T.; Luo, B.; Zhao, C. 2025. Application of machine learning to improve the accuracy of electrochemical sensors: a review. TrAC Trends in Analytical Chemistry 193: 118469.

Liu, N.; Zhao, G.; Liu, G. 2020. Coupling square wave anodic stripping voltammetry with support vector regression to detect the concentration of lead in soil under the interference of copper accurately. Sensors 20(23): 6792.

Martins, T.S.; Henrique, F.J.F.S.; Birolli, W.G.; Bott-Neto, J.L.; Silveira, H.C.S.; Esteves, P.M.; Oliveira Jr., O.N. 2024. Printed strips coated with a reticular organic framework for non-enzymatic detection of pesticides in the urine of rural workers. Chemical Engineering Journal 496: 154027.

Meliana, C.; Tan, M.T.T.; Loh, H.-S.; Meng, W.; Pang, C.H.; Low, S.S. 2026. Green electrochemical biosensor for food safety monitoring of carcinogenic acrylamide and formaldehyde. Bioelectrochemistry 168: 109122.

Nashruddin, S.N.A.B.M.; Salleh, F.H.M.; Yunus, R.M.; Zaman, H.B. 2024. Artificial intelligence-powered electrochemical sensor: recent advances, challenges, and prospects. Heliyon 10(18): e37964.

Smola, A.J.; Schölkopf, B. 2004. A tutorial on support vector regression. Statistics and Computing 14(3): 199-222.

Article originating from the Final Course Work of the Specialization in Project Management of the MBA USP/Esalq

To learn more about the course, click here and access the MBX Academy platform

You may also like

Project Management

November 19, 2026

Integrated Software for Operational Communication and Control: Practical Evidence in a Medium-Sized Company

The study analyzed the impacts of the lack of integration between commercial and operational modules of an integrated management software (ERP/CRM) in a medium-sized company in the mechanical engineering sector. The main objective was to evaluate practical evidence of communication and operational control optimization, identify bottlenecks, and formulate improvement proposals. A qualitative-quantitative approach was adopted through a single case study with documentary research, based on the extraction and filtering of historical task records from the Bitrix24 software and statistical correlation analysis between workload and allocated team. Based on the diagnosis, an action plan structured in the 5W2H tool was developed. The results revealed that 54.4% of the registered tasks consisted of duplicate, test, or practically useless records, generated by manual insertion during the scope transition between commercial CRM and engineering. It was also demonstrated that the increase in the commercial team linearly accompanied the growth of inefficient tasks, polluting the database and masking the organization’s real productive capacity. It was concluded that the automation of workflows and native integration between modules are essential to mitigate operational and financial risks, providing replicable guidelines for data governance in small and medium-sized enterprises.

Keywords: System Customization; Enterprise Resource Planning (ERP); Task Management; Management Software.

Project Management

November 19, 2026

Improvement of Inventory Management via Lean Six Sigma: Study in the Paper Industry

Organizations seek methodologies to reduce waste, increase efficiency, and become more competitive, promoting sustainable improvements in their processes. In this context, the study aimed to apply the Lean Six Sigma methodology, through the DMAIC cycle, to improve inventory management in a paper industry manufacturing pneumatic hoses, aiming to increase the accuracy between physical and systemic inventories and enhance the visual management of parts storage. The research was developed from the collection and analysis of data extracted from the company’s ERP system. Tools such as SIPOC, Ishikawa Diagram, and 5 Whys were used for the definition and identification of the root cause of the problem. As improvement proposals, a Digital Kanban system and an adaptation of the Two-Bin system, called the Three-Bin System, were implemented, in addition to the development of standardized operating procedures and the establishment of control mechanisms. The results demonstrated a significant improvement in inventory accuracy, raising the lowest identified index from 28% to 80%, and detected discrepancies between systemic and physical records equivalent to R$ 134,335.53. It was concluded that the application of Lean Six Sigma, combined with Project Management, represented an effective approach for conducting operational improvement projects, contributed to increased reliability of inventory information, to the improvement of material control processes, and to the strengthening of the organization’s operational management.

Keywords: Inventory accuracy; DMAIC; Visual management.

Project Management

November 19, 2026

Strategic Revitalization as a Vector for Competitive Repositioning in Urban Shopping Centers

The transformation of the shopping center sector, driven by the digitalization of retail and changes in consumer behavior, required the adoption of adaptation and competitive differentiation strategies. This study evaluated how strategic revitalization can act as a vector for competitive repositioning in a medium-sized urban shopping center located in the city of São Paulo. The research was applied in nature, with a quali-quantitative approach, using a single case study complemented by a field survey. The process was structured around the DMAIC cycle, encompassing the Define, Measure, Analyze, Improve, and Control phases. Bibliographic research, document analysis, semi-structured interviews were conducted, and a questionnaire was applied to 19 consumers to measure the perception of attractiveness, experience, and return intention. The results revealed gaps between the perceived and desired positioning, notably in the food court’s location (median 2.5) and the variety of gastronomic options (median 2.7). Revitalization opportunities were identified, focusing on the repositioning of the food court, the review of the tenant mix, and operational modernization. It was concluded that strategic revitalization has the potential to positively impact the development’s attractiveness and competitiveness indicators, provided that the proposed interventions in the Improve and Control phases of the DMAIC cycle are implemented.

Keywords: DMAIC Cycle; Competitive repositioning; Strategic revitalization; Shopping center; Tenant mix.

Project Management

November 19, 2026

Application of Project Practices in the Management of Personal Goals and Life Projects

The application of project management practices in personal life planning is still limited, despite many individual goals possessing project characteristics. This study analyzed the feasibility and relevance of adapting project management practices to personal life planning, focusing on early adulthood, and proposed a practical approach to organize, prioritize, and review individual goals. An exploratory survey was conducted through an electronic questionnaire with 90 participants, and the data were analyzed with the support of bibliographies on project management, portfolio, agile methods, risk management, and personal planning. The results indicated that most respondents defined personal goals but informally tracked them, and a significant portion abandoned important goals due to a lack of organization or planning. A positive receptiveness to applying project management concepts in personal life was observed, especially among participants under 35 years old. It was concluded that the adaptation of these practices is relevant and feasible, considering human and contextual particularities. As a practical contribution, a Personal Portfolio Management Framework was proposed to support the identification, categorization, prioritization, planning, tracking, and continuous review of individual goals.

Keywords: Self-management; Individual Planning; Prioritization.

Project Management

November 19, 2026

Optimization of sequencing in cell and gene therapies: an architecture of predictive and deterministic models

The challenge of production planning and sequencing in autologous cell and gene therapies, with an emphasis on the vein-to-vein cycle of CAR-T therapies, was analyzed. The study aimed to evaluate whether a hybrid architecture, composed of a predictive Machine Learning engine and a deterministic optimization engine, could improve planning robustness in the face of biological variability and GxP environment compliance constraints. To this end, an exploratory literature review guided by PRISMA 2020, validation of the main technical references, and a computational simulation with synthetic data were used. In the simulation, a Random Forest estimated processing times from synthetic biomarkers, and a deterministic model, equivalent to a MILP formulation, solved the batch sequencing on parallel resources with cleaning/setup time. The results indicated that the hybrid policy reduced the weighted average delay penalty to 18.67 penalty points, compared to 21.84 in static MILP and 75.25 in FIFO. It was concluded that the hybrid architecture contributed to optimizing production sequencing, showing favorable performance in extreme scenarios. The findings were interpreted as conceptual validation, not as clinical or industrial proof, due to the use of synthetic data and the influence of factors such as plant layout and real demand flow. The main contribution was to indicate, in a simulated and conceptual way, that the use of predictive estimates improves decision-making compared to deterministic models.

Keywords: CAR-T; Artificial Intelligence; Production Planning; Pharma 4.0; Gene Therapy.

Project Management

November 06, 2026

Technical-economic Feasibility of Two Automation Levels in the Transition of an Industrial System

The study analyzed the technical-economic justification of medium and long-term investments in industrial systems automation, focusing on plastic industry factories that still maintain a significant part of their operations in manual routines. In these environments, the investment decision is complex, as production already generates revenue, even with losses, rework, low traceability, and unreliable data. The objective was to compare the implementation of Human-Machine Interface (HMI) and supervisory systems at different production scales. The methodological approach was mixed and applied, developed from a project management perspective, considering cost, risk, operational safety, raw material quality, traceability, data governance, production continuity, and decision-making support. Four reference cases were compared: HMI on one line, HMI on seven lines, supervisory on one line, and supervisory on seven lines. The results indicated that the HMI contributed to organizing and standardizing local operations, while the supervisory system expanded the capacity to record information, track histories, generate reports, support audits, and investigate bottlenecks. It was concluded that the investment justification should not be limited to immediate returns but should consider the reduction of uncertainties, losses, operational risks, and costs that accumulate over time.

Keywords: Data governance; Risk management; Traceability; Supervisory; Decision making.